Engineering Transactions,
59, 3, pp. 235–248, 2011
10.24423/engtrans.147.2011
10.24423/engtrans.147.2011
Dynamic Compression Tests – Current Achievements and Future Development
In this paper a modified arrangement of the DICT technique was introduced. Miniatur- ization of bar and use of shadow principle to make a measurement of displacement allow to obtain strain rate up to 2.2×105 s−1. Commonly used methods of elimination of friction, iner- tia and adiabatic heating were presented. In order to estimate the rate sensitivity of a material (tantalum), quasi-static and SPHB tests were performed at room temperature within the rate spectrum ranging from 5×10−4 s−1 to 103 s−1. The final true stress versus true strain curves at different strain rates were corrected to a constant temperature and zero friction.
Keywords:
direct impact compression tests, tantalum, Hopkinson bars, miniaturized arrangement
Full Text:
PDF
Copyright © Polish Academy of Sciences & Institute of Fundamental Technological Research (IPPT PAN).